Micro Cable Air Heater "N"series

Micro Cable Air Heater

Features

  • 【Highly efficient, quick heating】
    Gas heating efficiency has been greatly improved thanks to the thin sheathed heating element and the exclusive bent structure.
  • 【Safe design】
    As the built-in thermocouple is directly mounted on the sheathed heater, the product can be used safely by controlling the temperature at or below the maximum operating temperature and thereby preventing the heater from overheating.

Types

MCA500N

MCA500N

Specification

All products listed are available in different voltages.

Rated voltage 200V 
Insulation resistance DC500V 5MΩ or above
Dielectric strength AC400V for one minute,current detection 10mA
Maximum operating temperature 500℃ (at built-in thermocouple)
Gas pressure Up to 0.3MPa (3kgf/cm2)
Material SUS316(sheathed heater, sheathed thermocouple),SUS304(tubular body)
Heated substance Air, inert gas, etc.

Configure of standard types

Rating 200V 500W
Flow rate 20Nℓ / min ~ 100Nℓ / min
Outlet tip temperature See the temperature characteristics graph.
Outlet/inlet joint PT3 / 8
Heater lead wire L500mm cut-off
Thermocouple Grounded K Type Compensation Lead Wire L2000mm(M4, Y terminal)

* Please contact us for any requests for customized heaters.

Temperature characteristics

Temperature characteristics

* The above outlet temperature was obtained with rated AC200V and the built-in thermocouple controlled at 500℃.

* The above temperature was obtained using a thermocouple mounted in a socket that was fixed on the outlet.

MCA1000N

MCA1000N

Specification

All products listed are available in different voltages.

Rated voltage 200V 
Insulation resistance DC500V 5MΩ or above
Dielectric strength AC400V for one minute,current detection 10mA
Maximum operating temperature 500℃ (at built-in thermocouple)
Gas pressure Up to 0.3MPa (3kgf/cm2)
Material SUS316(sheathed heater, sheathed thermocouple),SUS304(tubular body)
Heated substance Air, inert gas, etc.

Configure of standard types

Rating 200V 1000W
Flow rate 60Nℓ / min ~ 500Nℓ / min
Outlet tip temperature See the temperature characteristics graph.
Outlet/inlet joint PT3 / 4
Heater lead wire L500mm cut-off
Thermocouple Grounded K Type Compensation Lead Wire L2000mm(M4, Y terminal)

* Please contact us for any requests for customized heaters.

Temperature characteristics

Temperature characteristics

* The above outlet temperature was obtained with rated AC200V and the built-in thermocouple controlled at 500℃.

* The above temperature was obtained using a thermocouple mounted in a socket that was fixed on the outlet.

MCA1500N

MCA1500N

Specification

All products listed are available in different voltages.

Rated voltage 200V 
Insulation resistance DC500V 5MΩ or above
Dielectric strength AC400V for one minute,current detection 10mA
Maximum operating temperature 500℃ (at built-in thermocouple)
Gas pressure Up to 0.3MPa (3kgf/cm2)
Material SUS316(sheathed heater, sheathed thermocouple),SUS304(tubular body)
Heated substance Air, inert gas, etc.

Configure of standard types

Rating 200V 1500W
Flow rate 60Nℓ / min ~ 500Nℓ / min
Outlet tip temperature See the temperature characteristics graph.
Outlet/inlet joint PT3 / 4
Heater lead wire L500mm cut-off
Thermocouple Grounded K Type Compensation Lead Wire L2000mm(M4, Y terminal)

* Please contact us for any requests for customized heaters.

Temperature characteristics

Temperature characteristics

* The above outlet temperature was obtained with rated AC200V and the built-in thermocouple controlled at 500℃.

* The above temperature was obtained using a thermocouple mounted in a socket that was fixed on the outlet.

MCA3P3000N

MCA3P3000N

Specification

All products listed are available in different voltages.

Rated voltage 200V 
Insulation resistance DC500V 5MΩ or above
Dielectric strength AC400V for one minute,current detection 10mA
Maximum operating temperature 500℃ (at built-in thermocouple)
Gas pressure Up to 0.3MPa (3kgf/cm2)
Material SUS316(sheathed heater, sheathed thermocouple),SUS304(tubular body)
Heated substance Air, inert gas, etc.

Configure of standard types

Rating 3-phase 200V 3000W
Flow rate 100Nℓ / min ~ 1000Nℓ / min
Outlet tip temperature See the temperature characteristics graph.
Outlet/inlet joint PT1
Heater lead wire L500mm cut-off
Thermocouple Grounded K Type Compensation Lead Wire L2000mm(M4, Y terminal)

* Please contact us for any requests for customized heaters.

Temperature characteristics

Temperature characteristics

*The above outlet temperature was obtained with rated AC200V and the built-in thermocouple controlled at 500℃.

*The above temperature was obtained using a thermocouple mounted in a socket that was fixed on the outlet.

MCA3P5000N

MCA3P5000N

Specification

Rated voltage 200V 
Insulation resistance DC500V 5MΩ or above
Dielectric strength AC400V for one minute,current detection 10mA
Maximum operating temperature 500℃ (at built-in thermocouple)
Gas pressure Up to 0.3MPa (3kgf/cm2)
Material SUS316(sheathed heater, sheathed thermocouple),SUS304(tubular body)
Heated substance Air, inert gas, etc.

Configure of standard types

Rating 3-phase 200V 5000W
Flow rate 200Nℓ / min ~ 1500Nℓ / min
Outlet tip temperature See the temperature characteristics graph.
Outlet/inlet joint PT1
Heater lead wire L500mm cut-off
Thermocouple Grounded K Type Compensation Lead Wire L2000mm(M4, Y terminal)

* Please contact us for any requests for customized heaters.

Temperature characteristics

Temperature characteristics

*The above outlet temperature was obtained with rated AC200V and the built-in thermocouple controlled at 500℃.

*The above temperature was obtained using a thermocouple mounted in a socket that was fixed on the outlet.

Precautions when using this product

  • This product is for industrial use only.
  • Before turning on the heater, ensure that the gas is being supplied.
  • Ensure that the gas being supplied is at ambient temperature.
    (Please contact our sales staff to supply gases at non-ambient temperatures.)
  • Use the heater with the built-in thermocouple connected to a temperature control device and the temperature maintained at or below 500℃.
  • To stop the heater, first turn off the heater.
    Then, after ensuring that the temperature of the built-in thermocouple has dropped to or below 50℃, shut off the gas supply.
  • This product has been desighed for indoor use only and is not waterproof.
    Do not spill any liquid on the product.
Inquiry about the products
All products listed are available in different voltages.
Please contact us for a custom designed quote and/or for any questions about our products.